QINMING 2312 M/S VVI (SSI) ADVANTAGES
n Thickness 6mm , weight 20.8g.
n Inhibiting current 3.5μA, nominal service time more than 10 years.
n 9 exact programmer parameters meet the requirement of the patients perfectly;
n The exact pulse threshold, P/R amplitude test and lead impedance measurement;
n The function of events count,which is helpfull to analysis and diagnoses the state of pacemaker and situation of patient;
n Has the protection function of both runaway and crystal oscillatoer stop.
n Complete system self-chek and correction ensure the stability of the pacemaker;
n Programming and telemetry do not waste the energy of pacemaker battery, and prolong the longevities of pacemaker.
Qinming2312M/S Implantable Pacemaker Specifications
Parameters | Qinmin2312M | Qinmin2312S |
Pacing Mode | SSI(VVI),SST,SOO | |
Basic Rate | 30---(1)---60---100---(10)---160ppm | |
Magnet Rate | 90 ppm | |
Upper Rate | 180 ppm | |
Pulse Amplitude | 0.1---(0.1)--- 3.8 ---(0.1)---8.1 V | |
Pulse Width | 0.06…(0.06)…0.30,0.37…(0.06)… 0.85,0.92 …(0.06…)1.46,1.53,1.59 ms | |
Sensitivity | 0.5---(0.5)---2.5---10 mV | |
Refractory Period | 200---(25)---325---500 ms | |
Hysteresis | 0---(-50)---(-350) ms | |
Polarity Pace | Unipolar/bipolar | |
Polarity Sense | Unipolar/bipolar | |
Disturbed Pulse Rate | Basic Rate | |
ERT Indication | Basic Rate decrease11%; 2.Magnet Rate decrease11%; 3. Programmer shows ERT | |
Battery | WG9085,1.0Ah,2.8V | |
Current | 100% inhibited3.5μA;Standard Parameter 100% Pacing current9.2μA | |
Expected Service Time | 122months(Standard parameter 100% pacing) | |
Connector | IS-1 | |
Measurement/Weight | 48.5×41×6 mm/20.8 g | |
X-ray Identification | QM13 | |
Additional Functions | Interrogate: model, serial number, connector type, patient identifiers, implanted date, the latest programming date;Test battery voltagePacing event counterSensing event counterEMI event counterThreshold Test(with 0.1V resolution)P/R Amplitude TestLead impedance TestInterrogate: model, serial number, connector type, patient identifiers, implanted date, the latest programming date;Test battery voltagePacing event counterSensing event counterEMI event counter |
Note: 1.Underline parameter is Factory setting;
2. Sensitivity Test Wave is 2/13 triangle wave(International Standard wave);
3. Expected service time with formula:
Expected service time(year)=Battery available energy(Ah)×106/pacing current(μA)/24/365
qinming 2312s/m implantable pacemaker